Skip to content
ASTERON

SOL-03 / HYBRID

Hybrid Power Systems

A hybrid system combines firm thermal generation with solar PV and battery storage so each source does what it does best. The engineering is in the integration — and that is where ASTERON works.

Typical architecture — illustrative, not a project designOpen in Power Center Explorer

01 — Context

Why this needs engineering

Consider a site that needs 1.5 MW. A conventional supplier offers three 500 kW diesel gensets. That answers the capacity question, but not the operating one: how the plant behaves at partial load, how much fuel it burns over a year, and what happens when one unit is down.

Depending on the load profile, site and fuel logistics, a better answer may be diesel generation combined with solar PV and battery storage. Whether it is better — and in what proportions — is an engineering question, not a catalogue choice.

02 — Approach

How ASTERON designs it

We model the load against the available resources: generation that must stay online for stability, solar production across the day and the seasons, and what the battery is actually for — smoothing, spinning reserve, peak shaving or energy shifting.

From that we define the architecture: generator count and ratings, PV capacity, battery power and energy, the power conversion system, and the energy management system that dispatches them. The switchgear, protection and controls are designed as one system so the sources operate together safely.

03 — System scope

What the system includes

  1. 01

    Thermal generation

    Diesel and/or gas generator modules providing firm capacity and grid-forming support.

  2. 02

    Solar PV

    PV arrays and inverters sized against the daytime load and available area.

  3. 03

    Battery energy storage

    Battery system sized for its defined role, with thermal management for the climate.

  4. 04

    Power conversion system

    Bidirectional inverters connecting the battery to the AC system.

  5. 05

    Energy management system

    Supervisory control dispatching all sources against the load and operating rules.

  6. 06

    Transformers, switchgear and distribution

    The common electrical backbone that all sources connect to.

Applications

Where it is used

  • Off-grid industrial sites with high fuel logistics cost
  • Weak-grid sites needing firm supply and power quality
  • Operations with a significant daytime load
  • Existing diesel plants being extended with renewables

Design inputs

What we evaluate before specifying

  • Load profile by hour and season, not only peak demand
  • Minimum generator loading and system stability with high PV share
  • The defined role of the battery — and sizing power and energy for it
  • Available land or roof area and local solar resource
  • Control philosophy, operating modes and fallback on component failure
  • Capital cost against operating cost over the system lifetime

04 — How we work

From the first load data to a commissioned plant.

One accountable engineering team follows the project through every stage.

  1. Assess

    We study your load, site conditions and constraints, and define what the system has to do.

  2. Design

    We engineer the architecture: sources, protection, control and every interface between them.

  3. Select & Source

    We select equipment on technical merit and the manufacturing partners qualified to build it.

  4. Inspect & FAT

    We inspect during production and witness factory acceptance testing before release.

  5. Export & Deliver

    We prepare packing, documentation and conformity for international delivery.

  6. Supervise Installation & Commissioning

    Our engineers supervise installation and commissioning on site until the system performs.

05 — FAQ

Questions we are often asked

Is a hybrid system always better than a diesel-only plant?

No. It depends on the load profile, fuel cost and logistics, site conditions and how long the plant will operate. For some projects a well-configured diesel or gas plant is the right answer. We evaluate the options and explain the trade-offs.

What does the battery actually do in a hybrid plant?

That is a design decision. It can provide spinning reserve so fewer generators need to run, smooth solar fluctuations, shave peaks, or shift energy to the evening. Each role leads to a different battery size, so we define the role first.

Can you integrate with generators we already own?

Often, yes. We review the existing units, their controllers and the switchgear, then design the integration — including any control upgrades needed for the sources to operate together.

06 — Related

Continue exploring

Equipment

Diesel Generators

Diesel generator sets in open, canopied and containerised form, specified for duty and site conditions.

Equipment

Solar Panels & PV Equipment

PV modules, inverters and mounting systems selected for the climate and integrated with the plant controls.

Equipment

Control Systems

Generator controllers, power management and energy management systems coordinating every source in the plant.

Equipment

Switchgear

Low- and medium-voltage switchgear with synchronising, protection and metering for the complete plant.

Industry

Mining

Firm power for remote mine sites, processing plants and camps — designed around heavy motor loads and difficult logistics.

Start with your load

Tell us about your load. We’ll engineer the system.

Share what you know about your project — even if some of it is still undecided. Our engineers review every inquiry.

No price lists. Every proposal is engineered to your project.