Skip to content
ASTERON

SOL-02 / GAS

Gas Power Plants

Where a reliable gas supply exists, gas engines are a strong choice for long-hour and continuous operation. ASTERON engineers the complete plant around the fuel you actually have and the load you actually run.

Typical architecture — illustrative, not a project designOpen in Power Center Explorer

01 — Context

Why this needs engineering

Gas generation is sensitive to things a datasheet does not show: gas composition and methane number, supply pressure and its stability, and how quickly the load changes. A plant specified without these inputs can underperform from the first day.

Gas engines also accept load steps more gradually than diesel engines, which shapes how the plant must be configured for sites with large motors or sudden load changes.

02 — Approach

How ASTERON designs it

We begin with the gas: source, composition, pressure and availability. That determines engine selection, the gas train design and any conditioning required. We then configure the number of units and the control strategy for the load profile and duty.

Where the load is dynamic, we evaluate options such as load-step management, combining gas with diesel units, or adding battery storage to absorb transients — and we design the electrical system, cooling and ventilation as part of one coordinated scope.

03 — System scope

What the system includes

  1. 01

    Gas generator modules

    Engine-generator sets selected for the available fuel, duty and site conditions.

  2. 02

    Gas train and conditioning

    Pressure regulation, filtration, safety shut-off and metering matched to the supply.

  3. 03

    Synchronising and power management

    Load sharing, load-step control and start/stop sequencing.

  4. 04

    Transformers and switchgear

    Voltage transformation, protection and distribution interface.

  5. 05

    Cooling and ventilation

    Radiators, room or container ventilation and heat rejection designed for the climate.

  6. 06

    Heat recovery interface

    Provision for recovering engine heat where the facility can use it.

Applications

Where it is used

  • Continuous and baseload power for industrial facilities
  • Sites with pipeline natural gas or associated gas
  • Facilities that can use recovered heat
  • Long-hour operation where fuel logistics favour gas

Design inputs

What we evaluate before specifying

  • Gas composition, methane number and contaminants
  • Supply pressure, pressure stability and continuity of supply
  • Load-step behaviour and the largest sudden load change
  • Derating for ambient temperature and altitude
  • Ventilation, gas detection and safety systems
  • Maintenance intervals and access for long-hour duty

04 — How we work

From the first load data to a commissioned plant.

One accountable engineering team follows the project through every stage.

  1. Assess

    We study your load, site conditions and constraints, and define what the system has to do.

  2. Design

    We engineer the architecture: sources, protection, control and every interface between them.

  3. Select & Source

    We select equipment on technical merit and the manufacturing partners qualified to build it.

  4. Inspect & FAT

    We inspect during production and witness factory acceptance testing before release.

  5. Export & Deliver

    We prepare packing, documentation and conformity for international delivery.

  6. Supervise Installation & Commissioning

    Our engineers supervise installation and commissioning on site until the system performs.

05 — FAQ

Questions we are often asked

What gas information do you need to start?

Ideally a gas analysis, the supply pressure at the site boundary and the expected availability. If you do not have these yet, tell us the gas source and we will explain what needs to be confirmed.

Can gas engines handle large motor starts?

Gas engines accept load in smaller steps than diesel engines. For sites with large step loads we engineer around it — through plant configuration, load management, or by combining gas generation with diesel units or battery storage.

Can the plant run on LPG or biogas?

Engines are available for different gaseous fuels, but selection and ratings depend on the specific fuel. We confirm suitability against the actual gas composition for each project.

06 — Related

Continue exploring

Equipment

Gas Generators

Gas engine generator sets for natural gas, LPG and biogas, selected against the actual fuel and duty.

Equipment

Engines

Diesel and gas engines selected as the prime mover of the generator set, for the duty and service conditions of the project.

Equipment

Alternators

Low- and medium-voltage alternators specified for the electrical behaviour of the load they supply.

Equipment

Switchgear

Low- and medium-voltage switchgear with synchronising, protection and metering for the complete plant.

Equipment

Control Systems

Generator controllers, power management and energy management systems coordinating every source in the plant.

Industry

Oil & Gas

Power for upstream, midstream and downstream facilities, including generation from available field or associated gas.

Start with your load

Tell us about your load. We’ll engineer the system.

Share what you know about your project — even if some of it is still undecided. Our engineers review every inquiry.

No price lists. Every proposal is engineered to your project.