Skip to content
ASTERON

SOL-01 / DIESEL

Diesel Power Plants

Diesel generation remains the most widely deployable source of firm power. ASTERON engineers it as a plant, not a row of gensets: sized against your real load, synchronised, protected and delivered with everything needed to connect.

Typical architecture — illustrative, not a project designOpen in Power Center Explorer

01 — Context

Why this needs engineering

A diesel plant is often specified by dividing the required capacity by a convenient unit size. That shortcut ignores how the load actually behaves — motor starting, step loads, low-load running hours and the redundancy the operation really needs.

The result is frequently a plant that is oversized for most of its life, runs units at inefficient load points, and still struggles with the largest motor on site.

02 — Approach

How ASTERON designs it

We start from the load profile and the duty: continuous, prime or standby. From there we select the number and rating of generator modules, the redundancy philosophy and the synchronisation scheme so units share load and can be taken out for maintenance without interrupting supply.

The scope then extends to everything around the engines — step-up transformers where the distribution voltage requires it, main switchgear with protection and synchronising, fuel storage and transfer, cooling and ventilation, exhaust and acoustic treatment, and the power management system that ties it together.

03 — System scope

What the system includes

  1. 01

    Diesel generator modules

    Open, canopied or containerised sets selected for duty, ambient conditions and site altitude.

  2. 02

    Synchronising and power management

    Automatic synchronising, load sharing and load-dependent start/stop across the plant.

  3. 03

    Transformers

    Step-up or step-down units matched to the generation and distribution voltage levels.

  4. 04

    Main switchgear

    Generator and feeder panels with protection relays, metering and interlocking.

  5. 05

    Fuel system

    Bulk storage, day tanks, transfer pumps and filtration sized for the required autonomy.

  6. 06

    Balance of plant

    Cooling, ventilation, exhaust, acoustic enclosures, earthing and cabling.

Applications

Where it is used

  • Prime power for off-grid industrial sites
  • Standby power for critical facilities
  • Temporary and construction-phase power
  • Black-start and emergency supply for larger plants

Design inputs

What we evaluate before specifying

  • Load profile: base load, peaks, step loads and the largest motor start
  • Duty rating — continuous, prime or standby — and annual running hours
  • Redundancy philosophy and maintenance access without loss of supply
  • Derating for ambient temperature, altitude and dust
  • Fuel quality, storage autonomy and delivery logistics
  • Emissions and noise limits at the site boundary

04 — How we work

From the first load data to a commissioned plant.

One accountable engineering team follows the project through every stage.

  1. Assess

    We study your load, site conditions and constraints, and define what the system has to do.

  2. Design

    We engineer the architecture: sources, protection, control and every interface between them.

  3. Select & Source

    We select equipment on technical merit and the manufacturing partners qualified to build it.

  4. Inspect & FAT

    We inspect during production and witness factory acceptance testing before release.

  5. Export & Deliver

    We prepare packing, documentation and conformity for international delivery.

  6. Supervise Installation & Commissioning

    Our engineers supervise installation and commissioning on site until the system performs.

05 — FAQ

Questions we are often asked

How many generator sets does my project need?

It depends on the load profile, the duty and the redundancy you require — not only on the total capacity. Several smaller units can follow a variable load more efficiently and allow maintenance without interruption, while fewer larger units can simplify the plant. We evaluate both before recommending a configuration.

Can a diesel plant be extended with solar or battery storage later?

Yes, if it is planned for. We can design the switchgear, control system and site layout so that solar PV and battery storage can be integrated in a later phase without replacing the core plant.

Do you provide price lists for generator sets?

No. Every proposal is engineered to the project. After reviewing your requirements we issue a technical and commercial offer for the complete scope.

06 — Related

Continue exploring

Equipment

Diesel Generators

Diesel generator sets in open, canopied and containerised form, specified for duty and site conditions.

Equipment

Engines

Diesel and gas engines selected as the prime mover of the generator set, for the duty and service conditions of the project.

Equipment

Alternators

Low- and medium-voltage alternators specified for the electrical behaviour of the load they supply.

Equipment

Switchgear

Low- and medium-voltage switchgear with synchronising, protection and metering for the complete plant.

Equipment

Transformers

Power and distribution transformers matching generation, storage and distribution voltage levels.

Industry

Mining

Firm power for remote mine sites, processing plants and camps — designed around heavy motor loads and difficult logistics.

Start with your load

Tell us about your load. We’ll engineer the system.

Share what you know about your project — even if some of it is still undecided. Our engineers review every inquiry.

No price lists. Every proposal is engineered to your project.