Skip to content
ASTERON

SOL-05 / BESS

Battery Energy Storage

A battery energy storage system stores electrical energy and makes it available when required — helping optimise generator operation and integrate renewable generation. Its value depends entirely on what it is sized and controlled to do.

Typical architecture — illustrative, not a project designOpen in Power Center Explorer

01 — Context

Why this needs engineering

Battery storage is often requested as a capacity figure. But power and energy are separate decisions, and the right values follow from the job the battery must perform — a system providing spinning reserve looks very different from one shifting solar energy into the night.

Climate matters as well. Thermal management, enclosure design and fire protection must suit the site, particularly in hot or dusty environments.

02 — Approach

How ASTERON designs it

We define the role of the storage first, then size battery power and energy against the load profile and the other sources. We select the battery system and the power conversion system together, and specify the control functions required — grid-forming capability, black start, transfer behaviour.

The storage system is then integrated electrically and through the energy management system so that it works with generators, PV and the grid as one plant.

03 — System scope

What the system includes

  1. 01

    Battery system

    Containerised or cabinet battery racks with battery management system.

  2. 02

    Power conversion system

    Bidirectional inverters for charge and discharge, with the required control modes.

  3. 03

    Thermal management

    Cooling designed for the ambient conditions and duty cycle.

  4. 04

    Safety systems

    Detection, protection and suppression provisions for the enclosure.

  5. 05

    Transformer and switchgear interface

    Connection to the site electrical system with protection.

  6. 06

    Energy management integration

    Dispatch logic coordinating storage with all other sources.

Applications

Where it is used

  • Generator optimisation and spinning reserve
  • Peak shaving for grid-connected facilities
  • Renewable smoothing and energy shifting
  • Backup and ride-through for critical loads

Design inputs

What we evaluate before specifying

  • The defined storage objective and required autonomy
  • Sizing against the load profile rather than nameplate capacity
  • Generator optimisation and renewable smoothing requirements
  • Spinning reserve support and response time
  • Thermal management in hot climates
  • Safety provisions, siting and applicable standards

04 — How we work

From the first load data to a commissioned plant.

One accountable engineering team follows the project through every stage.

  1. Assess

    We study your load, site conditions and constraints, and define what the system has to do.

  2. Design

    We engineer the architecture: sources, protection, control and every interface between them.

  3. Select & Source

    We select equipment on technical merit and the manufacturing partners qualified to build it.

  4. Inspect & FAT

    We inspect during production and witness factory acceptance testing before release.

  5. Export & Deliver

    We prepare packing, documentation and conformity for international delivery.

  6. Supervise Installation & Commissioning

    Our engineers supervise installation and commissioning on site until the system performs.

05 — FAQ

Questions we are often asked

What size of battery do I need?

That depends on the role. Tell us what you want the storage to achieve — fewer generator running hours, peak shaving, backup duration, more solar — and we size power and energy against your load profile. If you are not sure, we can recommend the objective as part of the assessment.

Can a battery replace a generator?

In some configurations a battery can replace running reserve or cover short outages. For sustained supply it is usually combined with generation. The right balance is a design outcome.

06 — Related

Continue exploring

Equipment

Control Systems

Generator controllers, power management and energy management systems coordinating every source in the plant.

Equipment

Transformers

Power and distribution transformers matching generation, storage and distribution voltage levels.

Equipment

Switchgear

Low- and medium-voltage switchgear with synchronising, protection and metering for the complete plant.

Industry

Data Centers

Standby and prime power for data centers, designed to defined redundancy levels and tested before delivery.

Industry

Mining

Firm power for remote mine sites, processing plants and camps — designed around heavy motor loads and difficult logistics.

Start with your load

Tell us about your load. We’ll engineer the system.

Share what you know about your project — even if some of it is still undecided. Our engineers review every inquiry.

No price lists. Every proposal is engineered to your project.